ERETEC

Check out the latest news from Eretec.

:: Select Menu ::

Why Is Misalignment Important in High-Power WPT Testing?

High-Power WPT. Why MisalignmentMatters in EMF Testing

How Transmitter–Receiver Misalignment Affects Leakage Electromagnetic Fields and EMF Measurement Results

As high-power Wireless Power Transfer (WPT) technology expands into electric vehicles (EVs), automated guided vehicles (AGVs), autonomous mobile robots (AMRs), and industrial automation equipment, testing is becoming important not only for verifying power transfer efficiency but also for verifying electromagnetic field (EMF) exposure and electromagnetic compatibility (EMC). In particular, because WPT systems transfer power without physical contact between the transmitter (Tx) and receiver (Rx), their relative positions and alignment conditions can affect the operating characteristics of the system.

One of the important test variables in this context is misalignment. Misalignment refers to a condition in which the transmitter and receiver deviate from their reference alignment positions. It can include horizontal and vertical displacements, as well as tilting and rotation. In actual operating environments, the relative positions of the transmitter and receiver may vary depending on vehicle parking position, ground clearance, loading conditions, and equipment installation tolerances.

These positional changes affect more than just power transfer efficiency. Changes in the magnetic coupling conditions between the transmitter and receiver can also alter the distribution of leakage magnetic fields around the system. Therefore, in EMF testing of high-power WPT systems, measurement results obtained under aligned conditions alone are insufficient to fully characterize the electromagnetic field characteristics of the system.

In actual high-power WPT testing, it is important to identify the positional conditions under which high levels of leakage electromagnetic fields occur and establish a test environment capable of repeatedly reproducing those conditions.

1. How Does Misalignment Change the Electromagnetic Field Distribution in WPT Systems?

The relative positions of the transmitter and receiver affect magnetic coupling and leakage magnetic fields.

Inductive Power Transfer (IPT) is a method of transferring power to a receiver coil using an alternating magnetic field generated by a transmitter coil. During this process, the magnetic coupling between the transmitter and receiver is influenced by factors such as coil structure, spacing, relative position, and orientation.

The magnetic coupling conditions between the two coils may differ depending on whether the transmitter and receiver are aligned at their designed reference positions or displaced horizontally or vertically. These changes affect not only power transfer characteristics but also the spatial distribution of magnetic fields around the transmitter and receiver.

In particular, high-power WPT systems must account for leakage magnetic fields extending into the surrounding space, in addition to the magnetic fields formed between the transmitter and receiver. Leakage magnetic fields vary depending on the system structure and operating conditions, and the alignment of the transmitter and receiver is also an important influencing factor.

In an experimental study of a 25 kW IPT system, Mohamed et al. (2019) considered the possibility that increasing misalignment between the transmitter and receiver could increase leakage electromagnetic fields around the system. The researchers presented an approach for measuring electric and magnetic fields under various alignment conditions in an IPT system installed on an actual electric shuttle vehicle and identifying operating conditions under which high EMF levels occur.

An important point demonstrated by this study is that the relationship between misalignment and leakage electromagnetic fields cannot be adequately explained by a single numerical value. Measurement results may vary depending on the direction and magnitude of displacement between the transmitter and receiver, changes in the spacing between the two devices, and the power output conditions under which the system operates.

Therefore, it should not be generalized that leakage magnetic fields always increase at the same rate whenever misalignment occurs. In actual testing, various alignment conditions must be compared to identify unfavorable electromagnetic field conditions for the WPT system being evaluated.

2. What Misalignment Conditions Should Be Considered in WPT Testing?

Test conditions should be defined by distinguishing X, Y, and Z displacements from Pitch, Roll, and Yaw.

Misalignment in WPT systems does not simply refer to a situation in which the transmitter and receiver are displaced laterally. In actual testing, the relative positions and orientations of the transmitter and receiver can be examined in terms of multiple degrees of freedom (DOF).

Horizontal X and Y displacements refer to conditions in which the transmitter and receiver move forward, backward, or sideways from their reference positions. Z displacement represents a change in the vertical distance between the two devices, known as the Air Gap. These displacements may occur due to vehicle parking position, changes in ground clearance, or the stopping position of industrial mobile equipment.

Rotational conditions can also be considered alongside positional displacements. Pitch, Roll, and Yaw represent tilting and rotation relative to the reference coordinate axes and are used to describe situations in which the relative orientations of the transmitter and receiver change.

In their study of a 25 kW IPT system, Mohamed et al. (2019) considered X, Y, and Z displacements, as well as Pitch, Roll, and Yaw, to investigate operating conditions under which high EMF levels could occur. In the actual measurements, the researchers compared various X and Y alignment conditions and Air Gap conditions to evaluate electromagnetic field characteristics associated with changes in the relative positions of the transmitter and receiver.

However, this does not mean that all WPT tests must evaluate the six variables over identical ranges. The required misalignment ranges depend on the product being tested, its mechanical structure, actual operating conditions, and applicable test requirements.

When designing test infrastructure, the important first step is not to determine the positioning accuracy of a specific positioner, but to define the range of positional variations that may occur in the actual WPT system. Positioning devices and fixtures should then be designed to reproduce these conditions repeatedly.

3. Why Is It Important to Identify the Worst-Case Condition in Misalignment Testing?

Measurements under aligned conditions do not always represent the maximum EMF levels.

In EMF testing of high-power WPT systems, it is difficult to evaluate the full range of operating conditions using only electromagnetic field values measured under reference alignment conditions. Changes in the relative positions of the transmitter and receiver can alter the magnetic field distribution, and certain misalignment conditions may produce higher leakage magnetic fields than those observed under reference alignment conditions.

For this reason, identifying the Worst-Case Condition, or the most unfavorable electromagnetic field condition among those being evaluated, is an important part of testing.

To investigate the Worst-Case Condition, the system’s rated power output, operating frequency, transmitter and receiver structures, and reference spacing must first be defined. Positional displacements and orientation changes that may occur within the actual operating range can then be established as test conditions, allowing the electric and magnetic fields measured under each condition to be compared.

Mohamed et al. (2019) also presented an approach that first identifies the Worst Operating Condition, considering that high EMF levels may occur under various alignment conditions. The purpose of this approach is to identify conditions under which high exposure levels are likely to occur in the actual system and then perform measurements and evaluations focused on those conditions.

One important consideration is that the Worst-Case Condition does not necessarily correspond to the condition with the greatest positional misalignment between the transmitter and receiver. The conditions under which the maximum leakage magnetic field occurs may be influenced by factors such as the system’s coil structure, magnetic coupling, power control, and load conditions.

Furthermore, it cannot be assumed that the condition producing the highest magnetic field at one measurement location will produce the same result at other measurement locations. Therefore, the Worst-Case Condition must be determined by considering not only positional displacement but also measurement locations and actual operating conditions.

This approach extends WPT testing beyond a procedure that verifies a single measurement value at rated power output, transforming it into a validation process that compares electromagnetic field characteristics across various operating conditions.

4. Why Is It Important to Control EMF Measurement Locations Alongside Misalignment?

Even within the same WPT system, measurement results vary depending on the measurement location and Probe height.

If misalignment affects the electromagnetic field distribution in a WPT system, the location at which these fields are measured also becomes an important consideration.

Electric and magnetic fields around a WPT system may not be spatially uniform. Measurement values can vary depending on the distance from the transmitter and receiver, measurement height, and relative position to vehicle structures.

In particular, for WPT systems used in electric vehicles, it is necessary to distinguish between the area around the transmitter and receiver beneath the vehicle, the exterior of the vehicle, and the vehicle interior when evaluating accessibility and human exposure conditions.

In the experimental study of a 25 kW IPT system, the researchers distinguished the area beneath the vehicle where the transmitter and receiver were located, the surrounding areas of the vehicle, and the vehicle interior as separate EMF evaluation regions. Around the vehicle, measurement locations were selected based on points where high electromagnetic field levels were expected. Inside the vehicle, a coordinate system was defined relative to the center of the receiver, and the magnetic field distribution was examined by varying measurement positions and heights.

The study also observed a tendency for magnetic field strength to decrease as measurement height increased. This demonstrates that measurement results can vary with changes in Probe position and distance, even under the same system and operating conditions.

Therefore, accurately controlling the positions of the transmitter and receiver alone is not sufficient for misalignment testing. The measurement position and height of the EMF Probe, its distance from the DUT, and its measurement orientation must also be clearly defined and repeatedly reproduced.

For example, even if the transmitter and receiver are set to the same misalignment condition, variations in Probe height or position between measurements may make it difficult to determine whether differences in the results are caused by actual changes in the electromagnetic field or by differences in measurement location.

In other words, this explains why the Positioning System used in high-power WPT testing must account for the reproducibility of measurement device positions as well as those of the transmitter and receiver.

5. What Is Required to Improve the Reliability of Misalignment Testing?

In addition to measurement equipment accuracy, positioning control and the repeatability of test conditions are important.

To ensure the reliability of high-power WPT testing, it is necessary not only to use accurate EMF measurement equipment but also to reproduce the same test conditions repeatedly.

Even if the measurement equipment is properly calibrated, direct comparison of test results may become difficult if the relative positions of the transmitter and receiver, Probe measurement locations, and power output and load conditions vary between tests. In particular, when evaluating changes in leakage magnetic fields caused by misalignment, positioning repeatability is important because the positional conditions themselves are major test variables.

To achieve this, test infrastructure must incorporate both Fixtures that securely hold the transmitter and receiver in place and Positioners that implement positional changes. The Positioner must be capable of providing the X, Y, and Z movement ranges and rotational conditions required for testing and should be configured to repeatedly establish the same positional conditions.

A fixture structure is also required to consistently maintain reference positions when the DUT is removed and reinstalled or when the same device is tested multiple times.

During measurement, the positions of the transmitter and receiver and the Probe position should be managed separately, and the test conditions under which each measurement value was obtained must be recorded. Managing information such as power output, load, and operating mode can also help compare results obtained under different misalignment conditions.

This management of test conditions can be integrated with an automation system. In this approach, the positions of the transmitter and receiver are changed according to a predefined test sequence, measurements are performed under each condition, and the measurement values and positional information are stored together.

For example, measurements can begin under reference alignment conditions, followed by sequential changes in X-direction displacement, Y-direction displacement, and Air Gap conditions, with EMF values recorded for each condition. The stored positional and operating conditions can then be used when repeating the same test sequence or comparing results before and after DUT design changes.

This does not mean that a specific automation method is mandatory for all WPT tests. The required level of automation may vary depending on the test subject and evaluation objectives. However, in high-power WPT testing involving repeated positional changes and multiple measurement locations, an integrated structure connecting Positioning, Measurement, Automation, and Data Management is useful for improving test efficiency and result traceability.

6. Conclusion

The key to misalignment testing is not the positional error itself, but the accurate reproduction of various operating conditions.

In high-power WPT systems, misalignment is not simply a matter of installation error or power transfer efficiency. Changes in the relative positions of the transmitter and receiver can affect magnetic coupling and the distribution of leakage electromagnetic fields, which may in turn alter EMF measurement results and unfavorable operating conditions.

An experimental study of a 25 kW IPT system demonstrates this relationship in an actual vehicle environment. The study examined operating conditions under which high EMF levels could occur by considering X, Y, and Z displacements, as well as Pitch, Roll, and Yaw, and evaluated electric and magnetic fields at multiple measurement locations around and inside the vehicle. This supports the need to consider alignment conditions, measurement locations, power output, and operating conditions together when evaluating EMF in high-power WPT systems.

From a test infrastructure perspective, obtaining an accurate measurement value at a specific location only once is not sufficient. It is necessary to implement the required misalignment conditions within the actual operating range, repeatedly reproduce the positions of the transmitter, receiver, and Probe, and consistently record and compare the measurement values obtained under each condition.

These requirements extend high-power WPT testing beyond the performance of individual EMF measurement instruments to the design of test infrastructure that integrates Positioning, Measurement, Automation, and Data Management.

In conclusion, managing misalignment in high-power WPT testing means more than simply aligning the transmitter and receiver. It involves establishing a test system capable of reproducing the various positional conditions that may occur during actual operation and reliably comparing the resulting electromagnetic field characteristics.

References

Mohamed, A. A. S., Meintz, A., Schrafel, P., & Calabro, A. “Testing and Assessment of EMFs and Touch Currents From 25-kW IPT System for Medium-Duty EVs.” IEEE Transactions on Vehicular Technology, 68(8), 7477–7487. DOI: https://doi.org/10.1109/TVT.2019.2920827