Antenna Chamber
Key Features:
Efficient Over-the-Air Antenna Pattern Measurement
Compact, anechoic absorber-lined RF enclosure
Self-contained, built on a moveable cart system
No special installation of construction required
Ideal as a shared resource for Pre-Compliance testing
EMQuestTM Data Acquisition and Analysis Software
Test Measures:
- Active and Passive Antennas
- 2-D/3-D Antenna Patterns
- Antenna Pattern Measurement
  Vector and Scalar Quantities
- TRP,EIRP
- TIS,EIS
- NHPRP,NHPIS
WATCH THE VIDEO ON THE 8050 - CLICK HERE.

The ETS-Lindgren Model 8050 Antenna Measurement System is compact, fully anechoic RF enclosure for antenna pattern measurements. The AMS-8050 is freestanding and built on a moveable cart configuration; it fits into parent buildings without special installation or construction. This over-the-air test system for wireless device measurement may be used for:

  • Rapid prototyping of wireless devices
  • Design validation
  • Pre-certification testing
  • Performance measurement
  • Production sampling
The AMS-8050 is an ideal solution when space is a limitation as it is a self-contained, test lab for making fast, over-the- air performance measurements of small wireless devices and mobile handsets, as well as short range APM. Integrated drawers allow components required for testing to remain with the system. It is incorporated into a movable chassis so the entire system may be transported between different test stations. The ability to transport the system and store all components within the cart makes it an ideal solution for multiple research and development groups.

Small in size but big on operational throughput, the AMS 8050 System lets you make fully automated 2-D (polar) and 3-D (spherical) antenna pattern measurements. You can measure quantities such as : total radiated power (TRP), effective isotropic radiated power (EIRP), total isotropic sensitivity (TIS), effective isotropic sensitivity (EIS), near-horizon partial radiated power (NHPRP), and near-horizon partial isotropic sensitivity (NHPIS). If you?re using an external test house for certification testing, our system can help you go fully prepared. Over-the-air measurements made in the AMS 8050 have shown good correlation to measurements made in larger, fully compliant chambers. Use the AMS 8050 System to make tests during product development, and you ll shorten the time to certification.

System diagram. Top cut view of the AMS-8050 anechoic chamber and test instrumentation (Shown with customer-supplied computer, wireless communications tester, spectrum analyzer, vector network analyzer and cables. Model 2090 Controller?OPT1 and cables shown in black are included with the system.

Data Acquisition and Analysis Software
The AMS 8050 System includes our versatile EMQ 100 Antenna Pattern Measurement Software. The software makes fully automated (pattern and frequency response) measurements for both active and passive antennas, including their vector and scalar qualities, in either transmit or receive mode.

Post-processing capabilities include calculations for directivity, gain, radiation efficiency, total radiated power and total isotropic sensitivity. EMQ 100 also calculates industry specific quantities such as Near-Horizon Partial Radiated Power and Near- Horizon Partial Isotropic Sensitivity required by the CTIA Over-The-Air Performance Test Plan.

Advanced graphic capabilities allow data to be shown in a variety of 2-D and 3-D formats, exported to Microsoft Excel?, PDF files or saved in Microsoft RTF format.

Standard Configuration
  • Fully anechoic test chamber with RF shielded door
  • RF connecting cables (up to RF Switch)
  • SAM phantom mount
  • SAM phantom head
  • Model 3126 precision sleeve dipole antennas (3) with center frequencies of 880, 1845 & 2140 MHz
  • EMQuest EMQ 100 Antenna Pattern Measurement Software
  • Multi-Axis Positioner (MAPS)
  • ETS-Lindgren Model 2090-OPT 1 Positioner Controller
  • Vertical and horizontal path loss fixture for calibration
  • Free space antenna mount
  • Model 3164-04 Diagonal Dual Polarized Horn Antenna (700 MHz - 6 GHz)
  • Outer dimensions (L x W x H) 8 ft. x 4 ft. x 6 ft. (2.53m x 1.30m x 1.85m)
  • Communication antenna installed in the enclosure ceiling
  • Operational Training Video
  • Approximate weight: 1,800 lbs (816.5 kg)
  • RF Shielded hatch, opening dimensions 30 in. x 30 in. (76.2cm x 76.2cm)
  • Electrical power filter for drive system motors (installed in drive cart)
  • Electrical power filter for equipment and DUT outlets (installed in the system cart with one IEC outlet strip)
  • Type N feed-through connector (1)
  • SMA feed-through connector (1)
  • SMA feed-through rotating connector (1)
Options
  • Infrared (IR) Camera System
    The IR camera system including monitor, power filter and required cables, allows the user to observe the EUT while a test is in progress. This option includes: a camera panel module with integrated RF filter, a 15-inch LCD monitor, cameral power supply and a BNC video cable.
Portable Computing Device (PCD) Mount
The portable computing device mount allows center rotation of small to medium size notebook, laptop, or tablet devices. The weight limit is 15 lbs (6.8 kg). The mount will accommodate a 4.5 in. deep x 10.5 to 14 in. wide x 15.5 in. long (11.43 cm x 26.67 to 35.56 cm x 39.37cm) device.
Measurement Capability
Scalar Pattern Measurements
  • Single-Axis Single-Polarization Pattern Measurement
  • Single-Axis Dual-Polarization Pattern Measurement
  • Two-Axis Single-Polarization Pattern Measurement
  • Two-Axis Dual-Polarization Pattern Measurement
Vector Pattern Measurements
  • Vector Single-Axis Single-Polarization Pattern Measurement
  • Vector Single-Axis Dual-Polarization Pattern Measurement
  • Vector Two-Axis Single-Polarization Pattern Measurement
  • Vector Two-Axis Dual-Polarization Pattern Measurement
Sensitivity Pattern Measurements
  • Single-Axis Single-Polarization Sensitivity Pattern Measurement
  • Single-Axis Dual-Polarization Sensitivity Pattern Measurement
  • Two-Axis Single-Polarization Sensitivity Pattern Measurement
  • Two-Axis Dual-Polarization Sensitivity Pattern Measurement
Response Measurements
  • Response Measurements
  • Vector Response Measurements
  • Full S-Parameter Measurement
  • Communication Tester Frequency Response Measurement
Special Note: The dimensions illustrated are the minimum clearances required, with a small allowance on each side to pass the system through doorways and corridors. If these dimensions are not met, the AMS-8050 may be split into two sections (System Cart, Drive Cart). Contact ETS-Lindgren Sales at the time of order if you determine there is a need to split the system
CAUTION: If using an elevator to locate the system, verify the elevator will accommodate the size and weight ( 816.5 kg/1800 lb) of the system and accompanying personnel before attempting the movement.
Antenna Frequency Range Path Length Positioner Shield Performance Dimensions (L x W x H) Weight Power Requirements

Measurement Antenna Model
3164-04

700 MHz - 6 GHz

1.5m (Nominal) Accuracy 0.2 deg
Resolution 0.1 deg

 

>90 dB

 

Approximate Clearance

2.53m x 1.3m x 1.85m
8ft x 4 ft x 6ft
680 kg
1500lb
Drive System 208-240 VAC 50-60 Hz 10A NEMA 6-15

Equipment/DUT 115/230 VAC 50-60 Hz 5A NEMA 5-15